Safety & Warnings

Electric Towel Rails must be installed by a licensed electrician in accordance with the current IEE wiring regulations. The product should be permanently fixed and connected to the 220/240 Volt AC mains power supply via a fused spur/cable outlet, and earth bonded. This product is a Class 1 unit and as a result it must be earth connected. The element must NEVER be used without the towel rail or radiator being filled with water or fluid at correct fluid level. Only use the device in a suitable towel rail or radiator, for space heating and/or towel drying. This element should be mounted vertically and in the BOTTOM of the towel rail; it can be mounted horizontally only when it is in the ambient temperature control mode. It is imperative that you have the correct fluid level (90% fluid of towel rail total volume is recommended) in the towel rail before the element is used. Never attempt to disconnect the control unit from the heating element. It is a unit that was factory-sealed. Ensure the O-ring is on the connection part before installation; this o-ring is preventing the leakage after installation. Always use the correct tools (Spanner). Comes with Cable Cover.

Useful Features

Boost mode - If you need a short boost Maximum heating performance, then press the button on the control unit, boost time option is 2 and 4 hours. The element will stay working at the setting boost hours at maximum performance. After heating at the setting hours, it will revert back to previous chosen mode and temperature.

Over heated protection - If the automatic control system is faulty and the water temperature in the radiator is increasing in an uncontrolled manner, the system has two safety mechanisms to prevent excessive pressure in the radiator. Firstly, the entire system is completed shut down electronically when a water temperature of 95°C is reached. If this protection mechanism fails for whatever reason, a simple downstream thermal fuse ensures complete shut-down

Freeze protection - Once the control unit is in “STANDBY” mode (Power on), The control unit has an automatic freeze-protection setting. The default setting for frost protection is between 7°C and 15°C. If the radiator temperature falls below 7°C,the heating system switches on automatically, heats the liquid in the radiator to 15°C and then switch off again. An Ice symbol appears on the display.

Room temperature compensation - As the NTC that measures the room temperature and feeds back information to the controller is located on the back of the controller, it is close to the warm radiator. The measured temperature will therefore not accurately reflect the temperature in other part of the room. For this reason, there is an automatic temperature adjustment of -3°C in the control unit.

Open window/open door detection - This automatic function detects when the temperature falls by 2°C or more over a short period of time. In this case, the system assumes that this reduced temperature is due to opened windows or open doors, “OP” will be displayed on the controller unit and the heating system is switched off automatically and will be active to heat automatically once the temperature is detected back to stable condition.

Note: The image above shows both the chrome and the anthracite models - this listing is for the ANTHRACITE model.

Model No.

  • Model: TRAC-BREI-LABL-CTTE
  • Manufactured by: Reina

Reviews

Reina Touch Thermostatic Element - Anthracite
[TRAC-BREI-LABL-CTTE]



There are currently no product reviews.
NOTE: Reviews may require prior approval before they will be displayed


Details

  • Model:
    [TRAC-BREI-LABL-CTTE]
  • Manufactured by: Reina

Description

Safety & Warnings

Electric Towel Rails must be installed by a licensed electrician in accordance with the current IEE wiring regulations. The product should be permanently fixed and connected to the 220/240 Volt AC mains power supply via a fused spur/cable outlet, and earth bonded. This product is a Class 1 unit and as a result it must be earth connected. The element must NEVER be used without the towel rail or radiator being filled with water or fluid at correct fluid level. Only use the device in a suitable towel rail or radiator, for space heating and/or towel drying. This element should be mounted vertically and in the BOTTOM of the towel rail; it can be mounted horizontally only when it is in the ambient temperature control mode. It is imperative that you have the correct fluid level (90% fluid of towel rail total volume is recommended) in the towel rail before the element is used. Never attempt to disconnect the control unit from the heating element. It is a unit that was factory-sealed. Ensure the O-ring is on the connection part before installation; this o-ring is preventing the leakage after installation. Always use the correct tools (Spanner). Comes with Cable Cover.

Useful Features

Boost mode - If you need a short boost Maximum heating performance, then press the button on the control unit, boost time option is 2 and 4 hours. The element will stay working at the setting boost hours at maximum performance. After heating at the setting hours, it will revert back to previous chosen mode and temperature.

Over heated protection - If the automatic control system is faulty and the water temperature in the radiator is increasing in an uncontrolled manner, the system has two safety mechanisms to prevent excessive pressure in the radiator. Firstly, the entire system is completed shut down electronically when a water temperature of 95°C is reached. If this protection mechanism fails for whatever reason, a simple downstream thermal fuse ensures complete shut-down

Freeze protection - Once the control unit is in “STANDBY” mode (Power on), The control unit has an automatic freeze-protection setting. The default setting for frost protection is between 7°C and 15°C. If the radiator temperature falls below 7°C,the heating system switches on automatically, heats the liquid in the radiator to 15°C and then switch off again. An Ice symbol appears on the display.

Room temperature compensation - As the NTC that measures the room temperature and feeds back information to the controller is located on the back of the controller, it is close to the warm radiator. The measured temperature will therefore not accurately reflect the temperature in other part of the room. For this reason, there is an automatic temperature adjustment of -3°C in the control unit.

Open window/open door detection - This automatic function detects when the temperature falls by 2°C or more over a short period of time. In this case, the system assumes that this reduced temperature is due to opened windows or open doors, “OP” will be displayed on the controller unit and the heating system is switched off automatically and will be active to heat automatically once the temperature is detected back to stable condition.

Note: The image above shows both the chrome and the anthracite models - this listing is for the ANTHRACITE model.